# Forefront Wireless Operations Portal
> **Status:** Scoped & Documented — awaiting build
> **Started:** July 25, 2026
> **Domain:** my.forefrontwireless.com
> **Access:** Dual — staff (role-based) and customer self-service
Single pane of glass for Forefront Wireless operations and customer self-service. Staff get a real-time network dashboard aggregating MikroTik routers, Ubiquiti backhauls & CPEs, switches, PDUs, UPSs, and environmental monitors. Customers get account management and a service upgrade marketplace. All driven by four backend data sources — Splynx, UISP, MikroTik RouterOS, and Zabbix/SNMP.
---
## Access Model — Role-Based (Staff) + Customer
```
my.forefrontwireless.com
├── /login
├── /staff/* ← role-gated
└── /customer/* ← customer-gated
```
### Staff Roles
| Role | Permissions | Who |
|------|------------|-----|
| **Admin** | Full CRUD — devices, customers, SNMP templates, billing overrides, user management | Germaine |
| **Tech** | Read-write limited — troubleshoot customer issues, view all equipment, run diagnostics, reset CPEs, but no billing changes or user management | Contractors, support staff |
| **View Only** | Read-only across all dashboards — no config changes, no customer data mutation | Auditors, occasional helpers |
**Implementation:** Role stored in portal's own user table (not Splynx roles — Splynx is source-of-truth for billing, portal has its own auth). Contractors get Tech role by default.
### Customer Access
- Login (email + password, or magic link)
- Tied to their Splynx customer record
- Can only see their own account, services, and usage
- No network-level visibility
---
## Staff Dashboard — Real-Time Network Ops
The staff landing page is a grid of live-status cards grouped by device category:
### Section 1: MikroTik Routers
**Source:** MikroTik REST API (direct)
**Devices:** 5 × CCR2004
| Widget | Data |
|--------|------|
| Router status | Online/offline, uptime |
| CPU / Memory | Live gauges |
| Aggregate throughput | Total in/out across all interfaces |
| Per-router drill-down | Interface stats, queues, DHCP leases, ARP |
### Section 2: Ubiquiti Backhauls (Point-to-Point Links)
**Source:** UISP API
| Widget | Data |
|--------|------|
| Link status | Up/down, signal strength (dBm) |
| Capacity | Current throughput vs max |
| List view | All P2P links with AirMax stats |
### Section 3: Customer CPEs (Ubiquiti)
**Source:** UISP API
| Widget | Data |
|--------|------|
| CPE status | Online/offline count, last seen |
| Signal health | Signal/chain stats from subscriber devices |
| Search | By customer name → linked CPE |
| Actions (Tech) | Reboot CPE, re-associate |
### Section 4: MikroTik Switches
**Source:** MikroTik REST API (or SNMP via Zabbix proxy)
| Widget | Data |
|--------|------|
| Switch status | Online/offline per switch |
| Port utilization | % used, PoE budget |
| VLAN membership | Trunk/access port map |
### Section 5: PDUs & UPSs (Algcom)
**Source:** SNMP (via Zabbix or direct SNMP poll)
| Widget | Data |
|--------|------|
| PDU outlet status | On/off per outlet, current draw |
| UPS status | Battery charge %, load %, runtime remaining |
| Alerts | On battery, low battery, overload |
### Section 6: Environmental (TPDIN Web Monitor 3)
**Source:** SNMP (via Zabbix or direct) **+** web URL scrape
| Widget | Data |
|--------|------|
| Temperature | Current, min/max 24h |
| Humidity | Current % |
| Contact sensors | Door open/closed, water detected |
| Web UI link | Direct link to TPDIN interface |
---
## Device Inventory & SNMP Template Auto-Generation
Staff (Admin/Tech) can add new devices via the portal UI:
### Add Device Form
| Field | Example | Purpose |
|-------|---------|---------|
| **Make** | Algcom, MikroTik, TPDIN, Ubiquiti | Manufacturer |
| **Model** | ALG-PDU-8, CCR2004, W-M3 | Model identifier |
| **Category** | Router / Switch / PDU / UPS / Environmental / Backhaul / CPE | Dashboard section |
| **IP Address** | 10.x.x.x | SNMP target |
| **SNMP Community** | public / custom | For SNMP polling |
| **Web URL** | http://10.x.x.x | Direct link from dashboard |
| **SNMP Template** | algcom-pdu, tpdin-wm3, mikrotik-switch | Dropdown — existing templates |
### Auto-Template Engine
When a new make/model is added that has no existing template, the backend:
1. **Probes SNMP** — walks `1.3.6.1.2.1` (standard MIB) to discover available OIDs
2. **Identifies device** — matches sysDescr / sysObjectID against known patterns
3. **Suggests template** — maps discovered OIDs to widget types (gauge, status, counter, text)
4. **Staff approves** — one-click to save as reusable template for that make/model
Once a template exists for a make+model, any new device added with that combination inherits it automatically.
### Template Schema (per make/model)
```json
{
"make": "Algcom",
"model": "ALG-PDU-8",
"category": "pdu",
"poll_interval_seconds": 60,
"widgets": [
{
"name": "Outlet 1 Current",
"oid": "1.3.6.1.4.1.x.x.x.1",
"type": "gauge",
"unit": "A",
"warning_threshold": 8,
"critical_threshold": 10
}
]
}
```
---
## Architecture — 4-Source Aggregation
```
┌──────────────────────────────────────────────────────────────────────────┐
│ my.forefrontwireless.com │
│ ┌─────────────────────────┐ │
│ │ React SPA │ │
│ │ /staff/* │ /customer/* │ │
│ └───────────┬─────────────┘ │
└─────────────────────────────────┼────────────────────────────────────────┘
┌──────────────────────────────────────────────────────────────────────────┐
│ FastAPI Aggregation Backend │
│ │
│ ┌─────────┐ ┌─────────┐ ┌─────────┐ ┌──────────┐ ┌────────────────┐ │
│ │ Splynx │ │ UISP │ │MikroTik │ │ Zabbix │ │ Direct SNMP │ │
│ │ Adapter │ │ Adapter │ │ Adapter │ │ Adapter │ │ Poller │ │
│ └────┬────┘ └────┬────┘ └────┬────┘ └────┬─────┘ └───────┬────────┘ │
│ │ │ │ │ │ │
│ ┌────┴────┐ ┌────┴────┐ ┌────┴────┐ ┌────┴─────┐ ┌──────┴────────┐ │
│ │ Auth │ │ Role │ │ Device │ │ SNMP │ │ Template │ │
│ │ Service │ │ Manager │ │ Registry│ │ Template │ │ Engine │ │
│ └─────────┘ └─────────┘ └─────────┘ └──────────┘ └───────────────┘ │
└──────────────────────────────────────────────────────────────────────────┘
│ │ │ │
▼ ▼ ▼ ▼
┌──────────────┐ ┌──────────┐ ┌──────────────┐ ┌──────────────┐
│ Splynx v4.2 │ │ UISP │ │ MikroTik │ │ Zabbix │
│ Self-hosted │ │ (UNMS) │ │ RouterOS │ │ (on-prem │
│ │ │ app2 │ │ REST API │ │ or cloud) │
└──────────────┘ └──────────┘ └──────────────┘ └──────────────┘
billing/CRM network router stats SNMP infra
```
---
## Customer Portal Features
### Dashboard
- Active services (what plan am I on?)
- Current bill & due date
- Data usage (from MikroTik queue stats)
- Recent payments
### Account Management
- Update contact info (email, phone, address)
- Update payment method
- View invoice history
### Marketplace — Service Upgrades
- Browse available plans (from Splynx tariffs)
- Compare current plan vs upgrades
- Request upgrade (generates Splynx ticket or service change)
- See prorated cost before confirming
### Support
- Submit ticket (→ Splynx ticket system)
- View ticket status
- Outage notifications (opt-in SMS/email)
---
## Hardware Inventory — Known Devices
### Routers (MikroTik CCR2004 Series)
| Model | Ports | SFP+ | Cooling | Notes |
|-------|-------|:---:|---------|-------|
| [CCR2004-1G-12S+2XS](https://mikrotik.com/product/ccr2004_1g_12s_2xs) | 1× GbE, 12× SFP+, 2× SFP28 (25G) | ✓ 12+2 | Active | High-density fiber router |
| [CCR2004-16G-2S+PC](https://mikrotik.com/product/ccr2004_16g_2s_pc) | 16× GbE, 2× SFP+ | ✓ 2 | Passive | Silent, 300% faster than CCR1009 |
| [CCR2004-16G-2S+](https://mikrotik.com/product/ccr2004_16g_2splus) | 16× GbE, 2× SFP+ | ✓ 2 | Active | Best single-core perf/watt |
**Data source:** MikroTik REST API — status, CPU, memory, throughput, interface stats, DHCP, queues
### Switches (MikroTik CRS Series)
| Model | Ports | SFP+ | PoE | Form Factor |
|-------|-------|:---:|:---:|-------------|
| [CRS317-1G-16S+RM](https://mikrotik.com/product/crs317_1g_16s_rm) | 1× GbE, 16× SFP+ | ✓ 16 | — | 1U rack, dual PSU |
| [CRS309-1G-8S+IN](https://mikrotik.com/product/crs309_1g_8s_in) | 1× GbE, 8× SFP+ | ✓ 8 | — | Desktop |
| [CRS310-8G+2S+IN](https://mikrotik.com/product/crs310_8g_2s_in) | 8× 2.5GbE, 2× SFP+ | ✓ 2 | — | Desktop, ROS v7 |
| [CRS326-24G-2S+RM](https://mikrotik.com/product/CRS326-24G-2SplusRM) | 24× GbE, 2× SFP+ | ✓ 2 | ✓ Passive | 1U rack |
**Data source:** MikroTik REST API or SNMP — port map, PoE budget, VLAN memberships
### Backhauls (Ubiquiti Point-to-Point)
| Type | Models | Data Source |
|------|--------|-------------|
| AirMax / AirFiber P2P links | Various | UISP API |
**Data source:** UISP API — link status, signal strength (dBm), capacity %, firmware
### Customer CPEs (Ubiquiti Subscriber Devices)
| Type | Data Source |
|------|-------------|
| Ubiquiti CPE stations | UISP API |
**Data source:** UISP API — online/offline, signal health, last seen, reboot action (Tech role)
### DC Power Systems (PacketFlux)
| Device | Description | SNMP | Notes |
|--------|-------------|:---:|-------|
| [PacketFlux RackInjector](https://store.packetflux.com/packetflux-rackinjector/) | Modular DC power injector, hot-swappable, bench-repairable | ✓ via SiteMonitor | Individual port fuses, per-component replacement |
| [RackInjector Hardware Docs](http://packetflux.info/smri/rihw/ri-hardware/) | Installation & configuration manual | — | Internal component layout, power distribution |
**Data source:** SNMP via PacketFlux SiteMonitor system
### DC UPS & PDUs (Algcom)
| SKU | Model | Spec | SNMP | Notes |
|-----|-------|------|:---:|-------|
| [FN-4800-10-SNMP](https://www.ispsupplies.com/ALGcom-FN-4800-10-SNMP) | POWER ADVANCED 48-540-M | 540W / 10A, 48V DC UPS | ✓ | LiFePO4 compatible |
| [FN-4800-25-SNMP](https://www.ispsupplies.com/ALGcom-FN-4800-25-SNMP) | POWER ADVANCED 48-1350-M | 1350W / 25A, 48V DC UPS | ✓ | Larger capacity |
| [37030030001](https://www.ispsupplies.com/ALGcom-37030030001) | DC PDU Monitored 1U | 8× 10A outputs, 80A total, 1060 VDC | ✓ SNMPv2 | Per-outlet V/A/W, remote on/off, scheduling, undervoltage shutdown, Zabbix/Grafana/LibreNMS compatible |
**Data source:** SNMP — per-output voltage, current, power; battery charge/load/runtime for UPS models
### Environmental Monitors (TPDIN)
| Device | Data Source | Widgets |
|--------|-------------|---------|
| TPDIN Web Monitor 3 | SNMP + web URL scrape | Temperature, humidity, contact sensors (door/water) |
**Data source:** SNMP (temp/humidity/contacts) + HTTP scrape of web interface for backup data
---
## Build Phases
| Phase | What | Complexity |
|:---:|------|:---:|
| **1** | Splynx adapter + auth system + roles + customer dashboard | Medium |
| **2** | MikroTik adapter + staff router/switch dashboard | Medium |
| **3** | UISP adapter + backhaul/CPE dashboard | Medium |
| **4** | SNMP poller + template engine + PDU/UPS/environmental dashboard | High |
| **5** | Customer marketplace (plan comparison + upgrade flow) | Medium |
| **6** | Device registry UI + auto-template generation | High |
---
## Integration Dependencies
| Source | Adapter Type | Auth | Status |
|--------|-------------|------|:---:|
| Splynx | REST (HMAC-SHA256 signature) | Key + secret | ✓ Proven |
| UISP | REST (API token) | Settings → Users → API Access | Token needed |
| MikroTik | REST (basic auth) | Read-only API user per router | Users needed |
| Zabbix | REST (API token) | Zabbix API user | TBD — cloud migration |
| SNMP | Direct UDP poll | Community string per device | Template needed |
---
## Related
- **Splynx v2 docs:** https://api-doc.splynx.com/
- **UISP docs:** https://help.ui.com/hc/en-us/categories/360001181833-UISP
- **MikroTik REST API:** https://help.mikrotik.com/docs/display/ROS/REST+API
- **Zabbix API:** https://www.zabbix.com/documentation/current/en/manual/api
- **Git:** https://git.itpropartner.com/ippadmin/forefront-wireless-portal