65 lines
2.7 KiB
Markdown
65 lines
2.7 KiB
Markdown
# CHANGELOG — Forefront Wireless Operations Portal
|
||
|
||
---
|
||
|
||
## 2026-07-25 (PM #2) — Hardware Catalog Added
|
||
|
||
Linked and documented every known device model on the Forefront Wireless network:
|
||
|
||
**Routers:** CCR2004-1G-12S+2XS, CCR2004-16G-2S+PC, CCR2004-16G-2S+ (3 models)
|
||
**Switches:** CRS317-1G-16S+RM, CRS309-1G-8S+IN, CRS310-8G+2S+IN, CRS326-24G-2S+RM (4 models)
|
||
**DC Power:** PacketFlux RackInjector (modular, SNMP via SiteMonitor)
|
||
**DC UPS:** Algcom FN-4800-10-SNMP (540W/10A), FN-4800-25-SNMP (1350W/25A)
|
||
**DC PDU:** Algcom 37030030001 — 8× 10A outputs, per-outlet V/A/W, remote on/off, SNMPv2, Zabbix-compatible
|
||
**Environmental:** TPDIN Web Monitor 3 — SNMP + web scrape
|
||
**Links:** Ubiquiti AirMax/AirFiber P2P backhauls + subscriber CPEs (via UISP)
|
||
|
||
All devices have official product page links, specs, and data source annotations in the README.
|
||
|
||
---
|
||
|
||
## 2026-07-25 (PM) — Dual Access & Device Management Scoped
|
||
|
||
### Major Design Decisions
|
||
|
||
**Dual-access portal** — same domain, different views:
|
||
- `/staff/*` — role-gated (Admin, Tech, View Only)
|
||
- `/customer/*` — tied to Splynx customer record
|
||
|
||
**Three staff roles:**
|
||
| Role | Permissions |
|
||
|------|------------|
|
||
| Admin | Full CRUD — devices, billing, templates, users |
|
||
| Tech | Troubleshoot, view all equipment, reboot CPEs — no billing |
|
||
| View Only | Read-only dashboards |
|
||
|
||
**Staff dashboard = 6 device sections:**
|
||
1. MikroTik routers (5 × CCR2004) — status, CPU, throughput
|
||
2. Ubiquiti backhauls — point-to-point link signal/capacity
|
||
3. Customer CPEs — subscriber device health, reboot action
|
||
4. MikroTik switches — port map, PoE budget
|
||
5. Algcom PDUs & UPSs — SNMP-polled outlet/battery status
|
||
6. TPDIN Web Monitor 3s — environmental (temp/humidity/contacts)
|
||
|
||
**Device inventory with auto-SNMP templates:**
|
||
- Staff add devices with make, model, IP, SNMP community, web URL
|
||
- Backend probes SNMP for unknown make/model combos
|
||
- Maps discovered OIDs → widget suggestions
|
||
- Staff approves → reusable template saved
|
||
- Any new device with same make/model inherits template automatically
|
||
|
||
**Customer side:**
|
||
- Account/billing management
|
||
- Current package view
|
||
- Marketplace — browse upgrade plans, compare, request change
|
||
|
||
**Portal auth separate from Splynx** — Splynx is billing source-of-truth; the portal runs its own user table with roles. Customer accounts are linked to Splynx customer IDs.
|
||
|
||
---
|
||
|
||
## 2026-07-25 (AM) — 4-Source Architecture
|
||
|
||
Multi-source aggregation architecture: Splynx (billing/CRM), UISP (network management), MikroTik (router telemetry), Zabbix/SNMP (infrastructure monitoring). Build phases 1-4 defined. Zabbix migration options documented.
|
||
|
||
See earlier CHANGELOG entry for Splynx API reconnaissance details.
|