Anita Gateway Restart (Jul 7, 2026)

Anita's Hermes gateway stopped working when the restart-anita-gateway.sh cron executed. The restart succeeded but the new gateway started with no Telegram connection because:

Root cause 1: Bot token was wrong

The main gateway's Telegram bot token was in Anita's .env instead of her own bot token. Two gateways can't share the same bot token. When the restart happened, it tried to use the main token and got "Telegram bot token already in use (PID 1164)".

Fix: Anita's .env must have its own TELEGRAM_BOT_TOKEN (from her own BotFather creation), not a copy of the main token.

Root cause 2: Allowed users list blocked messages

Anita's TELEGRAM_ALLOWED_USERS only had Germaine's ID (5813481339). When Anita sent a message, the gateway logged Blocked unauthorized user 8200236464. She could send messages but they were silently dropped.

Fix: TELEGRAM_ALLOWED_USERS=5813481339,8200236464

Gateway restart limitation

hermes gateway restart cannot be run from within the gateway process itself — it kills the process before the command completes. Restarting Anita's gateway had to be done from a separate shell or via cron.

Data preservation

Anita's session database (/root/.hermes/profiles/anita/state.db, 16MB, 9 sessions) survived the restart intact. Gateway restarts do not touch the SQLite session store.

Needed for Anita to work

  1. Correct TELEGRAM_BOT_TOKEN in her .env
  2. TELEGRAM_ALLOWED_USERS includes her Telegram ID (8200236464)
  3. Gateway independently started (not sharing main gateway's bot)